;cpd.ini.iap - ini file for new DOE Cessna 206 system, change made at Bergstrom Aircraft ; by PJS on 1/29/2006 [CONTACTS] In case of problems, please contact one of the following Name Work Home Email (@noaa.gov) PRI Betsy Andrews +1(303)497-5171 +1(303)442-5142 Betsy.Andrews BAK Pat Sheridan +1(303)497-6672 +1(303)888-6602 Patrick.Sheridan #3 John Ogren +1(303)497-6210 +1(720)238-3066 John.A.Ogren #4 Anne Jefferson +1(303)497-6493 +1(303)579-9013 Anne.Jefferson #5 Allison McComiskey +1(303)497-6189 +1(303)669-8879 Allison.McComiskey [Global] ;Full path to the cpd executable (based on CPD), used when restarting (or if it is PATH, just "cpd") CPDBin=/bin/cpd ;Full path to the state file (again $(CPD)this) CPDState=/etc/cpdstate ;Path to the binarys, must have the trailing / BaseBin=/bin/ ;Instruments to spawn, HEADING:binary ;Or pause:time ;First the instruments Instrument=GPS:gps Instrument=UMAC1:umac ;Instrument=NEPH1:neph ;Instrument=CLAP:clap ;Instrument=PSAP3:psap3 Instrument=OZONEMON:ozonemon Instrument=RAWDATA1:rawdatarec;AOS Instrument=RAWDATA2:rawdatarec;MFR ;Instrument=WATLOW:watlow ;Now the controllers ;Instrument=LOVEPID1:lovepid Instrument=pause:1.0 Instrument=LOVEPIDUMAC1:lovepidumac Instrument=pause:1.0 ;Instrument=NEPH2M903:nephM903 ;Instrument=NEPH3M903:nephM903 ;Instrument=NEPH4M903:nephM903 ;Instrument=LFE:lfe Instrument=pause:1.0 Instrument=AEROSOL:aerosol Instrument=pause:2.0 Instrument=HUMIDOGRAPH:humidograph ;Wait to let aerosol spawn (others use it) Instrument=SCHEDULE:schedule Instrument=FLASK:flask ;Wait for others to spawn, aeromon reads from filter Instrument=pause:2.0 Instrument=AEROMON:aeromon ;Full path to the serial server, if null, looks in the instrument bin dir for sersrv, if it cant open the file as a full pathname, prepends the bin dir to it, or just sersrv if it's in PATH) SerSrvBin=/aer/prg/cpd/bin/sersrv ;List of headings that designate spanchecks Spancheck=SPANCHECK ;Spancheck=SPANCHECK-FAST ;List of uMACs, HEADING:id (id is hundreds digit on analog channels) uMAC=UMAC1:0 uMAC=LOVEPIDUMAC1:2 ;Heading that other instruments will open to get aerosol data Aerosol=AEROSOL ;Heading instruments open filter as (to bypass mainly) ;Filter=FILTER ;Heading that cpx will use to get aeromon data Aeromon=AEROMON ;Heading that cpx will use to get clap data Clap=CLAP ;Heading that cpx will use to get ups data Bestups=BESTUPS ;Heading that cpx will use to get gps data Gps=GPS ;Password for the client to use ;ClientPassword=cmdl ;ClientPassword=pnc [Disk] ;Place to create log files, must have the trailing / LogDir=/aer/iap/log/ ;Monitor file to use (gets the log timestamp appended) MonitorFile=CPDMON ;Time to rotate the files, hh:mm format LogRotateInterval=24:00 ;Do log rotation on the day boundary, regardless LogRotateOnDay=TRUE ;Interval to flush files, in minutes FlushInterval=15 ;First field after the timestamp (when writing records) StationID=IAP ;Maximum file size (more causes an auto-switch); in KB MaxFileSize=250 ;Default for unspcified logging or "GLOBAL" GlobalLogging=TRUE ;Interval to calculate averages GlobalAvgInterval=1:00 ;Default interval for logging, if not specified or set to GLOBAL, mm:ss GlobalLogInterval=1:00 [SPANCHECK] ;List of nephs to check Neph=NEPH1 Neph=NEPH2M903 Neph=NEPH3M903 Neph=NEPH4M903 ;Neph=NEPH2 ;Time to measure CO2 on spancheck, mm:ss SpanCO2Time=5:00 ;Air SpanAirTime=10:00 ;Time to flush with CO2 SpanCO2FlushTime=8:00 ;With air SpanAirFlushTime=4:00 ;Name for the clients to use ClientName=Spancheck [SPANCHECK-FAST] ;List of nephs to check Neph=NEPH1 ;Neph=NEPH2 ;Time to measure CO2 on spancheck, mm:ss SpanCO2Time=0:30 ;Air SpanAirTime=0:30 ;Time to flush with CO2 SpanCO2FlushTime=0:30 ;With air SpanAirFlushTime=0:30 ClientName=Spancheck - 30 second [SCHEDULE] ;Show window initially DefaultShow=TRUE ;Used to create status strings by the client ShortName=S ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Printable name (used mainly for error printing) NiceName=Schedule ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=SCHDUL ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;Neph to use, for zeroing Neph=NEPH1 ;uMAC to use for digital output Dig_uMAC=0 ;Digital channel for the pump uMAC_ChanPump_HiVac=2 ;For the heater uMAC_ChanHeater=3 ;For the flask uMAC_ChanFlask=4 ;Home airport waypoint name Home=KPNC ;Sampling site waypoint Site=CART ;Site=CO2 ;Currently are tasks enabled TasksEnabled=TRUE ;Time, seconds, to average for, after takeoff AvgTime=1 ;Time, seconds, to log (monitor) for, after takeoff MonTime=60 ;Tasks ;Numbers following task name explained in doc Task=SYSTEMSTARTED Task=TAKEOFF,30; m/s Task=ENROUTESITE,2; km from home Task=READYTOSAMPLE,5; sec on ambient ;Task=FLASK,10; km from SITE Task=ONSITE,6; km from SITE Task=ENROUTEHOME,7; km from HOME Task=READYTOLAND,5; sec on ambient Task=LANDING,10; m/s [GPS] ;Port description Port=/dev/ttyUSB5:4800N81 ;Show window initially DefaultShow=TRUE ;Printable name (used mainly for error printing) NiceName=GPS ;Used to create status strings by the client ShortName=G ;Extra sentence to send on comms init ExtraConfig=PGRMO,GPRMC,1 ExtraConfig=PGRMO,GPGGA,1 ;Waypoints NAME,lat,lon Waypoint=CART,36.60544,97.48908;AOS trailer at CART site Waypoint=KPNC,36.73667,97.10194 Waypoint=CO2,37.17,96.88;Carbon Lagrangian final waypoint ;Waypoint=OK56,36.7450,97.3495;Blackwell-Tonkawa airport ;Waypoint=H76,36.6717,96.4056;Pawhuska airport ;Waypoint=CMDL,39.9911,105.2610 ;This should be setuid root, so be careful with it! TimeSyncProg=/aer/prg/cpd/bin/gpstimeset ;Select timebase for logging (fast uses avg. time, slow uses monitor time) LogFast=TRUE ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=GPS001 ;Prepend this to all log entries LogPrepend= ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;Enable auto clock syncing DoAutosync=TRUE ;Maximum time delta to do an autosync (seconds), +-0.75 or so MaxClockDeviation=1.0 [NEPH1] ;Port description Port=/dev/ttyUSB0:9600E71 ;Printable name NiceName=TSI Neph-Ref ;Used to create status strings by the client ShortName=N ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=NEPH01 ;Prepend this to all log entries LogPrepend= ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;Strings to send during init, after all defaults InitStr=L1 InitStr=B255 ;Values to set SMZ=1 STA=1 STB=62 STP=30600 STZ=300 SMB=1 SP=75 ;Set lamp wattage to this on server exit SPexit=75 ;Times to zero check on, seconds into the hour ;ZeroAt=3598 ;Wavelengths Lambda_Green=550.0 Lambda_Red=700.0 [UMAC1] ;Port description Port=/dev/ttyUSB9:9600N81 ;Printable name NiceName=uMAC-1 ;Used to create status strings by the client ShortName=U ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=UMAC01 ;Address on uMAC chain Addr=0 ;Number of analog input channels to use CountAIch=24 ;Digital channels CountDch=2 ;Minium digital channel MinDch=0 ;Intial values for the analog out channels InitAO=0.0,2.2 ;Intial value for digital channels, hex, 2 digits per channel, ascending channel order, left to right InitDO=0100 [NEPH2M903] ;Port description Port=/dev/ttyUSB1:9600N81 ;Printable name (used mainly for error printing) NiceName=Neph-LowRH ;Used to create status strings by the client ShortName=P ;Are we logging? (initially, can be changed while running IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=NEPH02 ;Prepend this to all log entries LogPrepend= RH_SP=40 Chan_T_Inlet=9 ;Chan_RH_Output=-1;no outlet, not controlling lowRH neph Chan_RH_Inlet=201 Cal_T_Inlet=-42.2,100.0;071025/PJS;-40.0,100.0 Cal_RH_Inlet=-0.3049,1.0619;071025/PJS;0.0,1.0 Run_Averages=TRUE [NEPH3M903] ;Port description Port=/dev/ttyUSB2:9600N81 ;Printable name (used mainly for error printing) NiceName=Neph-MedRH ;Used to create status strings by the client ShortName=Q ;Are we logging? (initially, can be changed while running IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=NEPH03 ;Prepend this to all log entries LogPrepend= RH_SP=65.0 Chan_T_Inlet=10 Chan_RH_Output=200 Chan_RH_Inlet=202 Cal_T_Inlet=-42.0,100.0;071025/PJS;-40.0,100.0 Cal_RH_Inlet=-0.5415,0.9975;071025/PJS;0.0,1.0 ;P:I:D:pv_cal:out_cal[:P,min,max][:I,min,max][:D,min,max][|P:I:D:pv_cal:out_cal[:P,min,max][:I,min,max][:D,min,max]] ;P,I,D are the algorithm parameters ;pv_cal,out_cal are calibration polynomials ;P,min,max specifies the limts of the output before calibration ;I,min,max bounds the integral (not just its influence) ;D,min,max the maximum influence of the derivative RH_PID=1.0:60.0:0.7:0.0,1.0:0.0,1.0:I,-75,75:P,0,100 Run_Averages=TRUE [NEPH4M903] ;Port description Port=/dev/ttyUSB3:9600N81 ;Printable name (used mainly for error printing) NiceName=Neph-HighRH ;Used to create status strings by the client ShortName=R ;Are we logging? (initially, can be changed while running IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=NEPH04 ;Prepend this to all log entries LogPrepend= RH_SP=85 Chan_T_Inlet=11 Chan_RH_Output=201 Chan_RH_Inlet=203 Cal_T_Inlet=-41.4,100.0;071025/PJS;-40.0,100.0 Cal_RH_Inlet=-0.4041,0.9955;071025/PJS;0.0,1.0 ;P:I:D:pv_cal:out_cal[:P,min,max][:I,min,max][:D,min,max][|P:I:D:pv_cal:out_cal[:P,min,max][:I,min,max][:D,min,max]] ;P,I,D are the algorithm parameters ;pv_cal,out_cal are calibration polynomials ;P,min,max specifies the limts of the output before calibration ;I,min,max bounds the integral (not just its influence) ;D,min,max the maximum influence of the derivative RH_PID=1.0:60.0:0.6:0.0,1.0:0.0,1.0:I,-75,75:P,0,100 Run_Averages=TRUE [PSAP3] ;Port description Port=/dev/ttyUSB7:9600N81 ;Printable name (used mainly for error printing) NiceName=PSAP-3W ;Used to create status strings by the client ShortName=L ;Are we logging? (initially, can be changed while running ;In the watlow's case, this will just contain any errors it reports ;And will NOT be writen to on a regular basis IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=PSAP3W ;Prepend this to all log entries LogPrepend= ;Number of points to smooth with ;SmoothTC=60 ;Sample area in m^2 Area_m2=1.847E-5; 10/2005 PJS ;Detect filter changes (START,STOP,BOTH,NONE) Autodetect=STOP ;Instrument calibrations Cal_Bap=0.0,1.0 Cal_Tr=0.0,1.0 Cal_Q_slpm=0.09,0.99;070802/eja;0.2909,0.9475; 051027/PJS ;Filter transmittance correction Cal_TRCB=0.814,1.237 Cal_TRCG=0.814,1.237 Cal_TRCR=0.814,1.237 ;Create la_ records Run_Averages=TRUE [CLAP] ;Show window initially DefaultShow=FALSE ;Running in analog mode? (don't need Port if true) Analog=FALSE ;Port description Port=/dev/ttyUSB12:9600N81 ;Printable name (used mainly for error printing) NiceName=CLAP ;Used to create status strings by the client ShortName=L ;Are we logging? (initially, can be changed while running ;In the whatlow's case, this will just contain any errors it reports ;And will NOT be writen to on a regular basis IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=CLAP01 ;Prepend this to all log entries LogPrepend= ;Number of points to smooth with SmoothTC=60 ;Sample area in m^2 (only applies to serial) Area_m2=1.782E-5; area stamped on filter holder ;Detect filter changes (START,STOP,BOTH,NONE) Autodetect=BOTH ;Instrument serial number Serial_Number=0046 ;Channel for linear Bap (only used if Analog=TRUE) Chan_Bap_lin=1 ;log10 Bap Chan_Bap_log=2 ;Filter Transmittance Chan_Tr=3 ;Flow rate Chan_Q_slpm=4 ;Respective calibrations (Analog only) Cal_Analog_Bap_lin=0.0,1.0E-5 Cal_Analog_Bap_log=7.0,1.0,1E-6 Cal_Analog_Tr=0.0,0.2 Cal_Analog_Q_slpm=0.0,1.0 ;Instrument calibrations Cal_Bap=0.0,1.0 Cal_Tr=0.0,1.0 ;Cal_Q_slpm=0.1211,0.9475; 030426/PJS Cal_Q_slpm=-0.1109,1.0574; 050923/aj ;Cal_Q_slpm=0.0,1.0 ;Filter transmittance correction Cal_TRC=0.814,1.237; 030424/JAO [AEROSOL] ;Show window initially DefaultShow=FALSE ;Printable name (used mainly for error printing) NiceName=Aerosol ;Used to create status strings by the client ShortName=A ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=AEROSL ;Prepend this to all log entries LogPrepend= ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;uMAC to use for digital out Dig_uMAC=0 ;DOT channel for the impactor Dig_Chan_AnalyzerImpactor=1 ;For the bypass Dig_Chan_Bypass=2 ;Reference neph to use, the heading RefNeph=NEPH1 ;Humidified neph WetNeph=NEPH4M903 ;CN counter to use ;CNC=CNC1 ;Single-wavelength psap ;CLAP=CLAP ;3 wavelength PSAP PSAP3=PSAP3 ;Seconds to pause averaging after a valve change SecondsToFlush=10 ;Seconds to pause averaging at startup SecondsToSpinup=20 ;Use linear out for cn out CN_Out_Lin=FALSE ;Channel on uMAC to output to, -1 disables CN_uMAC_Chan=-1 ;MFC flow at STP, voltage interface is no longer supported ;MFC_Set_V=2.7 ;MFC_Set_V=2.2 ;MFC_Set_Q=22 ;MFC output channel, -1 disables ;MFC_uMAC_Chan=1 ;Should be the inverse of Cal_Q_Analyzer ;Cal_MFC_Out=0.0022564,0.099840,0.0,0.0 ;Default cut to use DefaultCut=COARSE ;Cutpoints, format is mm:ss(or just seconds), FINE/COARSE ;Cutpoint=00:00,COARSE ;Cutpoint=06:00,FINE ;Cutpoint=12:00,COARSE ;Cutpoint=18:00,FINE ;Cutpoint=24:00,COARSE ;Cutpoint=30:00,FINE ;Cutpoint=36:00,COARSE ;Cutpoint=42:00,FINE ;Cutpoint=48:00,COARSE ;Cutpoint=54:00,FINE ;uMAC channel assignments ;T&RH sensor pairs, -1 disables a channel ;Inlet sensor Chan_Inlet_T=8 Chan_Inlet_RH=200;inlet of TSI neph ;Humido preheater Chan_HumidoPreheat_T=10; medRHneph Chan_HumidoPreheat_RH=202 ;Humido controller Chan_HumidoControl_T=11; highRHneph Chan_HumidoControl_RH=203 ;Ambient Chan_Ambient_T=18 Chan_Ambient_RH=19 ;Sample Chan_Sample_T=9; lowRHneph Chan_Sample_RH=201 ;Rack Chan_Rack_T=16; current sensor, wired 060308/PJS Chan_Rack_RH=-1 ;uMAC internal sensor Chan_uMAC_T=60 ;dP sensors Chan_dP_Pitot=-1 Chan_dP_Purge=-1 Chan_dP_NephImp=-1 Chan_dP_Spare1=22 Chan_dP_Spare2=23 ;Flowrate sensors Chan_Q_Filter=-1 Chan_Q_Analyzer=15 Chan_Q_Spare3=12; LowRH Neph Flow Chan_Q_Spare4=13; MedRH Neph Flow Chan_Q_Bypass=14; HighRH Neph Flow Chan_Q_CNDrier=-1 Chan_Q_CN=-1 ;General Chan_Wind_S=-1 Chan_Wind_D=-1 ;Calibration info ;For T&RH sensors Cal_RefInlet_T=-273.15,1.0 Cal_WetInlet_T=-273.15,1.0 ;Cal_Inlet_T=-42.6,100.0;071025/PJS;-40.0,100.0 Cal_Inlet_RH=-1.2477,1.0572;071025/PJS;-0.627,1.055; 070602/eja ;Cal_Inlet_RH=-2.2129,1.2762,-0.0052,0.00004; 051206/PJS ;Cal_Inlet_RH=10.2,93.2;#004 021110/JAO ;Cal_Inlet_RH=-1.6,104.2;#004 021113/JAO ;Cal_Inlet_RH=-1.0,100.8;#004 030423/PJS ;Cal_Inlet_RH=-0.8639,106.75;#004 050909/aj ;Cal_Sample_T=-42.2,100.0;071025/PJS;-40.0,100.0 ;Cal_Sample_RH=10.2,93.2;#004 021110/JAO ;Cal_Sample_RH=-1.6,104.2;#004 021113/JAO ;Cal_Sample_RH=-0.8639,106.75;#004 050909/aj ;Cal_Sample_RH=-0.8639,1.0675;#004 050909/aj slope adjusted by PJS, 060130 ;Cal_Sample_RH=-2.1211,1.2641,-0.0059,0.00004; 051207/PJS Cal_Sample_RH=-0.3049,1.0619;071025/PJS;0.46,1.07;070602/eja Cal_HumidoPreheat_T=-42.0,100.;071025/PJS;-40.0,100.0 ;Cal_HumidoPreheat_T=-41.661,101.88; 041124/aj Cal_HumidoPreheat_RH=-0.5415,0.9975;071025/PJS;-1.84,1.06; 070531/eja new cal ;Cal_HumidoPreheat_RH=-1.3789,1.2182,-0.005,0.00003; 051206/PJS ;Cal_HumidoPreheat_RH=0.0,100.78;041124/aj Cal_HumidoControl_T=-41.4,100.0;071025/PJS;-40.0,100.0 ;Cal_HumidoControl_T=-40.802,100.63; 041124/aj Cal_HumidoControl_RH=-0.4041,0.9955;071025/PJS;0.0,1.0; uncalibrated sensor installed 070924/JAO ;Cal_HumidoControl_RH=-3.30,1.11; 070531/eja new cal ;Cal_HumidoControl_RH=-3.0684,1.0455; 051206/PJS;-1.9522,1.1617,-0.0037,0.00002; 051206/PJS ;Cal_HumidoControl_RH=-1.17,99.0;#001 020918/EJA ;Cal_HumidoControl_RH=6.8,93.6;#001 021110/JAO ;Cal_HumidoControl_RH=-2.1,101.2;#001 021113/JAO ;Cal_HumidoControl_RH=-1.5,104.2;#001 030423/PJS ;Cal_HumidoControl_RH=-1.113,104.55; 041124/aj ;Cal_HumidoControl_RH=-4.0952,109.65; 050909/aj ;Cal_Ambient_T=-40.0,100.0 Cal_Ambient_T=-39.4,100.0;080305/PJS@PNC;-41.0,100.0;071025/PJS;-39.5,100.0;070531/eja ;Cal_Ambient_RH=18.6,83.0;#003 021110/JAO ;Cal_Ambient_RH=-2.6,103.0;#003 021113/JAO ;Cal_Ambient_RH=-11.591,126.73;#003 050923/aj ;Cal_Ambient_RH=-4.388,100.02;080305/PJS@PNC;-4.10,105.75;070531/eja Cal_Ambient_RH=0.49,111.64;090112/CO Cal_Rack_T=0.0,10.0; current is 0-50 amps for 0-5 VDC Cal_Rack_RH=0.0,1.0 Cal_uMAC_T=0.0,1.0 Cal_RefNeph_T=-273.15,1.0 Cal_RefNeph_RH=0.0,1.0 Cal_WetNeph_T=-273.15,1.0 Cal_WetNeph_RH=0.0,1.0 ;Cal_WetNeph_RH=-0.20,0.93;#002 020918/EJA ;Cal_WetNeph_RH=12.2,0.891;#002 021110/JAO ;Cal_WetNeph_RH=-1.6,1.024;#002 021113/JAO ;Cal_WetNeph_RH=-0.1,1.012;#unk 030423/PJS ;Cal_WetNeph_RH=0.0,1.0078; 041124/aj ;Cal_WetNeph_RH=2.9474,0.96914; 050909/aj ;dP sensors Cal_dP_Pitot=0.0,1.0 Cal_dP_Purge=-60.9,113.3 Cal_dP_NephImp=-53.2,113.5 Cal_dP_Spare1=-191.7,317.0 Cal_dP_Spare2=-195.7,315.1 ;Flowrate sensors Cal_Q_Filter=0.0,0.0 Cal_Q_Analyzer=0.271,18.405;070603/PJS@Greenwoods;0.0,19.926; LFE volume flow cal by Fred Brechtel 2005 Cal_Q_Spare3=-3.0404,1.8563;070603/PJS@Greenwoods;-3.3213,2.0586; volume flow cal, 051123/PJS;-2.5,2.5;default Cal_Q_Spare4=-2.8498,1.8878;070603/PJS@Greenwoods;-3.2025,2.1314; volume flow cal, 051123/PJS;-2.5,2.5;default Cal_Q_Bypass=-2.6896,1.7866;070603/PJS@Greenwoods;-3.1209,2.1553; volume flow cal, 051123/PJS;-2.5,2.5;default ;Cal_Q_Spare3=-2.6161,1.5972;070603/PJS@Greenwoods;-2.4784,1.5380; standard flow cal, 051123/PJS ;Cal_Q_Spare4=-2.4559,1.6271;070603/PJS@Greenwoods;-2.3893,1.5912; standard flow cal, 051123/PJS ;Cal_Q_Bypass=-2.3263,1.5454;070603/PJS@Greenwoods;-2.3387,1.6129; standard flow cal, 051123/PJS ;Cal_Q_Analyzer=-0.0226,10.016 ;Cal_Q_Spare3=-1.119,0.814 ;Cal_Q_Spare4=0.0,0.0 ;Cal_Q_Bypass=0.0,0.0 Cal_Q_CNDrier=0.0,0.0 Cal_Q_CN=0.0,0.0 ;General Cal_Wind_S=0.0,0.0 Cal_Wind_D=0.0,0.0 [HUMIDOGRAPH] ;Show window initially DefaultShow=FALSE ;Printable name (used mainly for error printing) NiceName=Humidograph ;Used to create status strings by the client ShortName=H ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=HUMGR1 ;Prepend this to all log entries LogPrepend= ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;Watlow ;Watlow=WATLOW ;uMAC channel for the pump speed Pump_uMAC_ch=-1 ;uMAC channel for the pump range PumpRange_uMAC_ch=-1 ;If false, do not do any setpoints ;Scanning=TRUE Scanning=FALSE ;Initial (and default) setpoint ;ChanA,ChanB,ChanC,ChanD SP_init=0.0, 0.0, 0.0, L ;Setpoints ;Time (either seconds, or mm:ss, both after the hour),ChanA,ChanB,ChanC,ChanD Setpoint=0:00, 0.0, 0.0, 0.0, L Setpoint=10:00, 10.0, 0.0, -100.0, H Setpoint=20:00, 10.0, 10.0, -50.0, L Setpoint=30:00, 20.0, 10.0, 0.0, H Setpoint=40:00, 20.0, 20.0, 50.0, L Setpoint=50:00, 10.0, 20.0, 100.0, H [AEROMON] ;Show window initially DefaultShow=FALSE ;Printable name (used mainly for error printing) NiceName=Aerosol Contamination ;Used to create status strings by the client ShortName=M ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=AERMON ;Prepend this to all log entries LogPrepend= ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;CN counter to use for contamination control ;CNC=CNC1 ;Filter, used to log its dP sensors ;Filter=FILTER ;Maximum dP across the Neph impactor, -1.0 disables Max_NephImp_dP=-1.0 ;uMAC AIN channels for sensors uMAC_Chan_Stack_T=-1 uMAC_Chan_Pumpbox_T=-1 uMAC_Chan_Heater_T=-1 ;CNC contamination control ;CNC>this is always contaminated CNCC_Dirty=100000 ;CNC