;cpd.ini.pn2 - configuration file for PNNL PN2 system ; based on cpd.ini.pn1 for CHAPS, which was ; cleaned up, based on cpd.ini.pn2 ...Jan. 9, 2006/MSP ; Setup for CARES 2010; May 18,2010/MSP ; PSAP size correspond to S/N-77 ; Third copy of override drive for PN2 [Global] ;Full path to the cpd executable (based on CPD), used when restarting (or if it is PATH, just "cpd") CPDBin=/bin/cpd ;Full path to the state file (again $(CPD)this) CPDState=/etc/cpdstate ;Path to the binarys, must have the trailing / BaseBin=/bin/ ;Instruments to spawn, HEADING:binary ;Or pause:time ;First the instruments Instrument=CNC1:cnserial Instrument=NEPH1:neph Instrument=UMAC1:umac Instrument=LOVEPID1:lovepid Instrument=RAWDATA:rawdatarec Instrument=PSAP3:psap3 ;Now the controllers Instrument=pause:2.0 Instrument=LOVEPIDUMAC1:lovepidumac Instrument=pause:2.0 ;Must be here (after delay) if it is in analog mode (it uses the uMAC) Instrument=AEROSOL:aerosol ;Wait to let aerosol spawn (others use it) Instrument=pause:2.0 Instrument=AEROMON:aeromon ;Full path to the serial server, if null, looks in the instrument bin dir for sersrv, if it cant open the file as a full pathname, prepends the bin dir to it, or just sersrv if it's in PATH) SerSrvBin=/aer/prg/cpd/bin/sersrv ;List of headings that designate spanchecks Spancheck=SPANCHECK ;List of uMACs, HEADING:id (id is hundreds digit on analog channels) uMAC=UMAC1:0 uMAC=LOVEPIDUMAC1:2 ;Heading that other instruments will open to get aerosol data Aerosol=AEROSOL ;Heading that cpx will use to get aeromon data Aeromon=AEROMON ;Password for the client to use ;ClientPassword=cmdl [Disk] ;Place to create log files, must have the trailing / LogDir=/aer/pn2/log/ ;Monitor file to use (gets the log timestamp appended) MonitorFile=CPDMON ;Time to rotate the files, hh:mm format LogRotateInterval=24:00 ;Do log rotation on the day boundary, regardless LogRotateOnDay=TRUE ;Interval to flush files, in minutes FlushInterval=15 ;First field after the timestamp (when writing records) StationID=PN2 ;Maximum file size (more causes an auto-switch); in KB MaxFileSize=1024 ;Default for unspcified logging or "GLOBAL" GlobalLogging=TRUE ;Interval to calculate averages GlobalAvgInterval=1:00 ;Default interval for logging, if not specified or set to GLOBAL, mm:ss GlobalLogInterval=15:00 [SPANCHECK] ;List of nephs to check Neph=NEPH1 ;Time to measure CO2 on spancheck, mm:ss SpanCO2Time=5:00 ;Air SpanAirTime=10:00 ;Time to flush with CO2 SpanCO2FlushTime=10:00 ;With air SpanAirFlushTime=3:00 ;Name for the clients to use ClientName=Spancheck [CNC1] ;Port description Port=/dev/ttyUSB1:9600E71 ;Printable name (used mainly for error printing) NiceName=CNC3010-1 ;Used to create status strings by the client ShortName=C ;Type (3010, 3010Polled, 3703, Pulse) CNType=3010Polled ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=CNC001 ;Prepend this to all log entries LogPrepend= ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;Flow (cc/s) Q_cnc_cc_s=15.762;sn2258 May14,2010/MSP ;16.683;12/26/2006,EJA;25.52;020401/PJS ;Create ca_ records ;Run_Averages=TRUE ;Reference Neph [NEPH1] ;Port description Port=/dev/ttyUSB0:9600E71 ;Printable name NiceName=TSI Neph-1 ;Used to create status strings by the client ShortName=N ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=NEPH01 ;Prepend this to all log entries LogPrepend= ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;Strings to send during init, after all defaults InitStr=L1 InitStr=B255 ;Values to set SMZ=4 STA=1 STB=29 STP=30600 STZ=300 SMB=1 SP=75 ;Set lamp wattage to this on server exit SPexit=75 ;Times to zero check on, seconds into the hour ZeroAt=3420 ;Wavelengths Lambda_Green=550.0 Lambda_Red=700.0 Create na_ records Run_Averages=TRUE ;Aerosol rack uMAC [UMAC1] ;Port description Port=/dev/ttyUSB4:9600N81 ;Printable name NiceName=uMAC-1 ;Used to create status strings by the client ShortName=U ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=UMAC01 ;Address on uMAC chain Addr=0 ;Number of analog input channels to use CountAIch=24 ;Digital channels CountDch=2 ;Minium digital channel MinDch=0 ;Intial values for the analog out channels InitAO=0.0,3.0 ;Intial value for digital channels, hex, 2 digits per channel, accending channel order, left to right InitDO=0000 [AEROSOL] ;Show window initially DefaultShow=FALSE ;Printable name (used mainly for error printing) NiceName=Aerosol ;Used to create status strings by the client ShortName=A ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=AEROSL ;Prepend this to all log entries LogPrepend= ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;uMAC to use for digital out Dig_uMAC=0 ;DOT channel for the impactor Dig_Chan_AnalyzerImpactor=1 ;For the bypass Dig_Chan_Bypass=0 ;Reference neph to use, the heading RefNeph=NEPH1 ;Humidified neph ;CN counter to use CNC=CNC1 ;3 wavelength PSAP PSAP3=PSAP3 ;Seconds to pause averaging after a valve change SecondsToFlush=31 ;Seconds to pause averaging at startup SecondsToSpinup=90 ;Use linear out for cn out CN_Out_Lin=FALSE ;Channel on uMAC to output to, -1 disables CN_uMAC_Chan=-1 ;MFC voltage at STP MFC_Set_V=3.000 ;MFC output channel, -1 disables MFC_uMAC_Chan=-1 ;Default cut to use DefaultCut=FINE ;Cutpoints, format is mm:ss(or just seconds), FINE/COARSE Cutpoint=00:00,COARSE Cutpoint=06:00,FINE Cutpoint=12:00,COARSE Cutpoint=18:00,FINE Cutpoint=24:00,COARSE Cutpoint=30:00,FINE Cutpoint=36:00,COARSE Cutpoint=42:00,FINE Cutpoint=48:00,COARSE Cutpoint=54:00,FINE ;uMAC channel assignments ;T&RH sensor pairs, -1 disables a channel ;Inlet sensor Chan_Inlet_T=-1 Chan_Inlet_RH=-1 ;Humido preheater Chan_HumidoPreheat_T=-1 Chan_HumidoPreheat_RH=-1 ;Humido controller Chan_HumidoControl_T=-1 Chan_HumidoControl_RH=-1 ;Ambient Chan_Ambient_T=17; May 18,2010/MSP ;-1; No sensor connected, Feb. 27, 2009, MSP ;17 ;was -1;sensor to uMAC AnIn#4; MSP, May 2, 2007 Chan_Ambient_RH=16; May 18,2010/MSP ;-1; No sensor connected, Feb. 27, 2009, MSP ;16 ;was -1; MSP, May 2, 2007 ;Sample Chan_Sample_T=9 ; analog 0 input 2 Chan_Sample_RH=201 ; RS-485 ;Rack Chan_Rack_T=14;was -1/Just small test, no sensor,MSP May 5, 2010 ;-1; No sensor connected, Feb. 27, 2009, MSP ;14;was -1/MSP June 17, 2007 Chan_Rack_RH=202; May 18,2010/MSP ;-1 ;Stack Chan_Stack_T=8 ; analog 0 input 1 Chan_Stack_RH=200 ; RS-485 ;Pumpbox Chan_Pumpbox_T=-1 Chan_Pumpbox_RH=-1 ;Heater Chan_Heater_T=-1 Chan_Heater_RH=-1 ;uMAC internal sensor Chan_uMAC_T=60 ;dP sensors Chan_dP_Pitot=19 ; excess stack flow dP, 4-20 mA port 0 Chan_dP_Purge=-1 Chan_dP_NephImp=20 ; impactor dP, dP port 1 Chan_dP_Spare1=-1 Chan_dP_Spare2=22 ; CN_vac, dP port 3 ;Flowrate sensors Chan_Q_Filter=-1 Chan_Q_Analyzer=203 ; MFC flow, RS-485 Chan_Q_Spare3=-1 Chan_Q_Spare4=-1 Chan_Q_Bypass=-1 Chan_Q_CNDrier=10 ; analog 1, input 1 (0-10 lpm) Chan_Q_CN=12 ; analog 2, input 1 (0-2 lpm) ;General Chan_Wind_S=-1 Chan_Wind_D=-1 Chan_P_ambient=-1 ;Calibration info ;For T&RH sensors Cal_RefInlet_T=-273.15,1.0 Cal_WetInlet_T=-273.15,1.0 Cal_Inlet_T=-40.0,100.0 Cal_Inlet_RH=0.0,100.0; May 18,2010/MSP ;0.8888,98.473 Cal_HumidoPreheat_T=-40.0,100.0 Cal_HumidoPreheat_RH=-0.0248,99.911 Cal_HumidoControl_T=-40.0,100.0 Cal_HumidoControl_RH=-1.2632,100.13 Cal_Ambient_T=-40.0,100.0 Cal_Ambient_RH=0.0,100.0 ; no calibr. par. available, May 1, 2007, MSP Cal_Sample_T=-40.0,100.0 Cal_Sample_RH=0.0,1.0; Apr. 3, 2009, MSP ;-1.59,1.06; May 1, 2007, MSP Cal_Rack_T=-40.0,100.0 Cal_Rack_RH=0.0,1.0; May 18,2010/MSP Cal_Heater_T=0.0 Cal_Heater_RH=0.0 Cal_Stack_T=-40.0,100.0 Cal_Stack_RH=0.0,1.0; June 13, 2007,MSP ;0.55,1.06; June 5, 2007, MSP Cal_Pumpbox_T=-40.0,100.0 Cal_Pumpbox_RH=0.0 Cal_uMAC_T=0.0,1.0 Cal_RefNeph_T=-273.15,1.0 Cal_RefNeph_RH=0.0,1.0 Cal_WetNeph_T=-273.15,1.0 Cal_WetNeph_RH=0.0,1.0 ;dP sensors Cal_dP_Pitot=0.0,1.0; -0.4358,3.94; Jan. 10, 2006, MSP Cal_dP_Purge=0.0 Cal_dP_NephImp=-187.6,307.0; -61.395,113.67; Jan. 10, 2006, MSP Cal_dP_Spare1=0.0 Cal_dP_Spare2=-187.6,307.0; -63.063,116.45 ;Flowrate sensors Cal_Q_Filter=-0.0461,9.7402 Cal_Q_Analyzer=0.0,1.0; 0.0,10.0 ; Jan. 10, 2006, MSP Cal_Q_Spare3=30.0 Cal_Q_Spare4=30.0 Cal_Q_Bypass=30.0 Cal_Q_CNDrier=0.1213,1.7545 Cal_Q_CN=-0.0172,0.3691 ;General Cal_Wind_S=0.0,10.0 Cal_Wind_D=180.0,72.0;aligned to true N/jao Cal_P_ambient=1000.0 [AEROMON] ;Show window initially DefaultShow=FALSE ;Printable name (used mainly for error printing) NiceName=Aerosol Contamination ;Used to create status strings by the client ShortName=M ;Are we logging? (initially, can be changed while running) IsLogging=GLOBAL ;Gets "_yyyymmdd_hhmm" appended to it, and used as the log out file LogBase=AERMON ;Prepend this to all log entries LogPrepend= ;Interval between log entries, in mm:ss, or GLOBAL (to use to default) LogInterval=GLOBAL ;CN counter to use for contamination control CNC=CNC1 ;Filter, used to log its dP sensors ;Filter=FILTER ;Maximum dP across the Neph impactor, -1.0 disables Max_NephImp_dP=100.0 ;CNC contamination control ;CNC>this is always contaminated CNCC_Dirty=999999.9 ;CNC